SP306R-VPX

3U VPX Air-Cooled Removable Storage Module

SP306R-CCVPX_3_mid_M

  • Removable Storage Module
  • PCIe (switched or point to point) interface
  • Up to 6 TB storage capacity in a single module
  • High Performance – Up to 2.2 GBytes/s in a single module
  • Low Power – 25 Watts
  • RAID 0/1 (Hardware based)
  • Scalable in capacity & bandwidth by adding more modules
  • Multi Function: Recorder, File Server, Direct attached storage

The SP306R-VPX StorePak™ is a removable single slot air-cooled 3U VPX storage module designed to be used either in conjunction with Critical I/O’s StoreEngine storage manager, or as a stand-alone Direct Attach Storage device. The StorePak™ is engineered for easy removal and replacement of on board storage since there are no cables to unplug to remove StorePak™. Specifically engineered for use in rugged embedded systems, StorePak™ provides unmatched storage functionality, high performance, high capacity, and scalability all within a small size, weight, and power (SWaP) footprint.

StoreEngine™ Products
Form Factor Recording Network File Services Direct Attached Storage Max Storage Capacity (per unit) Max Performance (per unit) RAID Levels IO Interface Options Model #
6U VPX air-cooled Yes Yes Yes 6 TB 750 MBytes/s 0/1/5 PCIe, GigE SE603-VPX
6U VPX cond-cooled Yes Yes Yes 6 TB 750 MBytes/s 0/1/5 PCIe, GigE SE603-CCVPX
3U VPX air-cooled Yes Yes Yes 1.5 TB* 750 Mbytes/s 0/1/5 PCIe, GigE SE300-VPX
3U VPX cond-cooled Yes Yes Yes 1.5 TB* 750 MBytes/s 0/1/5 PCIe, GigE SE300-CCVPX
*with optional expansion XMC

 

StorePak™ Products
Form Factor Product Family IO Interface Max Storage Capacity Max Performanc Scalable RAID 0,1 Removable Storage Recording & Network File Services Model #
6U VPX air-cooled StorePak PCIe (switched or point to point) 12 TB 2.5 GBytes/s Yes Hardware Based Yes if used with StoreEngine SP606R-VPX
6U VPX cond-cooled StorePak PCIe (switched or point to point) 12 TB 2.5 GBytes/s Yes Hardware Based Yes if used with StoreEngine SP606R-CCVPX
6U VPX air-cooled SataPak SATA (individual SATA drive connections) 1-6 SATA drives of 2TB each Up to 250 Mbytes/s for each drive No Host software based Yes No AP606R-VPX
6U VPX cond-cooled SataPak SATA (individual SATA drive connections) 1-6 SATA drives of 2TB each Up to 250 Mbytes/s for each drive No Host software based Yes No AP606R-CCVPX
3U VPX air-cooled StorePak PCIe (switched or point to point) 6 TB 2.0 GBytes/s Yes Hardware Based Yes if used with StoreEngine SP306R-VPX
3U VPX cond-cooled StorePak PCIe (switched or point to point) 6 TB 2.0 GBytes/s Yes Hardware Based Yes if used with StoreEngine SP306R-CCVPX
3U VPX air-cooled SataPak SATA (individual SATA drive connections) 1-6 SATA drives of 2TB each Up to 250 Mbytes/s for each drive No Host software based Yes No AP306R-VPX
3U VPX cond-cooled SataPak SATA (individual SATA drive connections) 1-6 SATA drives of 2TB each Up to 250 Mbytes/s for each drive No Host software based Yes No AP306R-CCVPX

 

Optional I/O Rear Transition Module (RTM) Products
Form Factor Description Interfaces Connectors Protocols Model Number
VPX RTM VPX RTM with XMC/PMC XMC/PMC
2x 1GbE
4x SATA
XMC/PMC
GbE - RJ45
SATA - SFF-8088
NAS (NFS) add'l dependent on XMC/PMC used RTM-VPX-MC1
VPX RTM 10GbE VPX RTM 2x 10GbE
2x 1GbE
4x SATA
SFP+ opitcal
GbE - RJ45
SATA - SFF-8088
NAS (NFS)
iSCSI, FCoE
RTM-VPX-10GE
VPX RTM 8Gb Fibre Channel VPX RTM 2x 8Gb FC
2x 1GbE
4x SATA
SFP+ optical
GbE - RJ45
SATA - SFF-8088
NAS (NFS) Fibre Channel RTM-VPX-8GFC